Compressed Air Foam Fire Extinguishing System and CAFS for Fire Trucks

In stock

Category:

Detail Information

Application: Mounted On Fire Trucks Mixed Liquid Flow Rate: 550-3500 L/min.
Fire Nozzle Spraying Distance: 25 Meters Roof Monitor Spraying Distance: 40 Meters
Water Pump: 1200-3600 L/min. Flow Rate Air Compressor: 5400-22000L/min. 37-160Kw
Foam Mixing Ratio: 0.1%-6% Foam Pump: 60L/min.-180L/min.
High Light:

CAFS Air Foam Fire Extinguishing System

,

CXFIRE Fire Extinguishing System

,

160Kw Fire Extinguishing System

Product Description

1. CAFS-60/6000 Compressed Air Foam Fire Extinguishing System for Fire Trucks

Model CAFS-60/6000
Flow Rate and Spray Performance

1. When outputting compressed air foam (CAF), the rated pressure is 0.75Mpa, and the rated mixed liquid flow rate is 600 L/min;

2. The maximum mixed liquid flow rate is 850L/min;

3. The spraying distance of the fire nozzle is 24 meters;

4. The spraying distance of fire monitors is 40 meters.

Water Pump

1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds.

2. Rated flow: 3600L/min; Rated pressure: 1Mpa.

Air Compressor

1. The maximum flow is 5400L/min@0.7Mpa, the maximum power is 37KW;

2. The maximum working pressure is 1.5Mpa;

3. The cooling method is water-cooled, with over-temperature automatic protection device.

Foam Mixing Ratio Unit

1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %;

2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 10L/min. The system has three pumps combined into a pump group, and the total flow is 30L/min.

Electric Control Unit Composed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus.

 

2. CAFS-900 Compressed Air Foam Fire Extinguishing System for Fire Trucks

Model CAFS-900
Flow Rate and Spray Performance

1. When outputting compressed air foam (CAF), the rated pressure is 0.75Mpa, and the rated mixed liquid flow rate is 550 L/min;

2. The maximum mixed liquid flow rate is 900L/min;

3. The spraying distance of the fire nozzle is 24 meters;

4. The spraying distance of fire monitors is 40 meters.

Water Pump

1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds.

2. Rated flow: 1200L/min; Rated pressure: 1Mpa.

Air Compressor

1. The maximum flow is 5400L/min@0.7Mpa, the maximum power is 37KW;

2. The maximum working pressure is 1.5Mpa;

3. The cooling method is water-cooled, with over-temperature automatic protection device.

Foam Mixing Ratio Unit

1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %;

2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 10L/min. The system has three pumps combined into a pump group, and the total flow is 30L/min.

Electric Control Unit Composed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus.

 

3. CAFS-1200 Compressed Air Foam Fire Extinguishing System for Fire Trucks

Model CAFS-1200
Flow Rate and Spray Performance

1. When outputting compressed air foam (CAF), the rated pressure is 0.8Mpa, and the rated mixed liquid flow rate is 1050 L/min;

2. The maximum mixed liquid flow rate is 1200L/min;

3. The spraying distance of the fire nozzle is 25 meters;

4. The spraying distance of fire monitors is 40 meters.

Water Pump

1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds.

2. Rated flow: 3600L/min; Rated pressure: 1Mpa.

Air Compressor

1. The maximum flow is 8400L/min@0.7Mpa, the maximum power is 55KW;

2. The maximum working pressure is 1.5Mpa;

3. The cooling method is water-cooled, with over-temperature automatic protection device.

Foam Mixing Ratio Unit

1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %;

2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 20L/min. The system has three pumps combined into a pump group, and the total flow is 60L/min.

Electric Control Unit Composed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus.

 

4. CAFS-MK3500 Compressed Air Foam Fire Extinguishing System for Fire Trucks

Model CAFS-MK3500
Flow Rate and Spray Performance

1. When outputting compressed air foam (CAF), the rated pressure is 0.8Mpa, and the rated mixed liquid flow rate is 3000 L/min;

2. The maximum mixed liquid flow rate is 3500L/min;

3. The spraying distance of the fire nozzle is 25 meters;

4. The spraying distance of fire monitors is 45 meters.

Water Pump

1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds.

2. Rated flow: 3600L/min; Rated pressure: 1Mpa.

Air Compressor

1. The maximum flow is 22,000L/min@0.7Mpa, the maximum power is 160KW;

2. The maximum working pressure is 1.3Mpa;

3. The cooling method is water-cooled, with over-temperature automatic protection device.

Foam Mixing Ratio Unit

1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %;

2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 20L/min. The system has nine pumps combined into a pump group, and the total flow is 180L/min.

Electric Control Unit Composed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus.

 

5. Company Reference Pictures 

   

   
 

MAIN CATEGORY